![]() They feature ball bearings that are double-sealed and permanently lubricated. Motors – The fan motors are Totally Enclosed Air-Over, squirrel-cage type, current pro-tected. The fan guards are constructed of heavy-gauge, rust-resistant, PVC (polyvinyl chloride)-coated steel wire. They are directly driven, and positioned for vertical air discharge. They are designed for maximum efficiency and are statically and dynamically balanced for vibration-free opera-tion. Low Sound Fans – The condenser fans are composed of corrosion resistant aluminum hub and composite blades molded into a low noise airfoil section. The design working pressure of the coil is 650 PSIG (45 barg). The cooler is covered with 3/4” (19mm) flexible, closed-cell, foam insulation (K≈0.25).Ī 40 mesh strainer (0.5 and 1.5 mm) is recommended upstream of the heat exchanger to prevent clogging.Ĭoils – Fin and tube condenser coils of seamless, internally-enhanced, high-condensing-coefficient, corrosion resistant copper tubes are arranged in staggered rows, mechani-cally expanded into aluminum fins. The heater provides freeze protection for the cooler down to -20☏ (-29☌) ambient. The cooler is equipped with a heater controlled by a separate thermostat. Water inlet and outlet connections are grooved for compatibility with factory supplied ANSI/AWWA C-606 connections. Installing con-tractor must include accommodations in the chilled water piping to allow proper drainage and venting of the heat exchanger. Compressor crankcase heaters are also included for extra protection against liquid migration.īrazed plate heat exchangers are UL (Underwriters Laboratories) listed. A large internal volume and oil reservoir provides greater liquid tolerance. All rotating parts are statically and dynamically balanced. The compressors incor-porate a scroll design that is compliant in both the axial and radial direction. The chiller has suction-gas cooled, hermetic, scroll compressors. Units are designed in accordance with NFPA 70 (National Electric Code), ASHRAE/ANSI 15 Safety code for mechanical refrigeration, ASME, Listed and labeled with Intertek Testing Services (ETL) and rated in accordance with the latest version of ARI Standard 550/590. Unit also includes service isolation valves as standard. Corrosion resistant wire mesh panels are added to protect the condenser coil from incidental damage and restrict unauthorized access to internal components. The steel is coated with baked-on powder paint, which, when subjected to ASTM B117 1000 hour, salt spray testing, yields a minimum ASTM 1654 rating of “6”. The unit structure is heavy-gauge, galvanized steel. After assembly, a complete operational test is performed with water flow-ing through the cooler to assure that the refrigeration circuit operates correctly. The unit is pressure-tested, evacuated, and fully charged with R-410A and includes an initial oil charge. The 15 - 65 Ton (53 - 218 kW) YCAL models are shipped complete from the factory ready for installation and use. Each unit includes hermetic scroll compressors, a liquid cooler, air cooled condenser, a charge of refrigerant R-410A, and a weather resistant microprocessor control center, all mounted on a rugged, formed-steel base. They are completely self-contained and are designed for outdoor (roof or ground level) installation. YORK Air-Cooled Scroll Chillers provide chilled water for all air conditioning applications using central station air handling or terminal units. Performance data provided in this document was created in accordance with Johnson Controls software: YORKworks version 13.02 and DXCHILL version 6.04
0 Comments
Leave a Reply. |